Installing 2x2 and 2x4 Panels

Please note- This panel requires professional installation and maintenance. The power supply must be disconnected before installing or maintaining the panel.  

Installation Instructions: 

1) Remove the old fixture and have the black and white input wires ready from the ceiling. 

2) Remove the connecting box on the top of panel by unscrewing the 2 screws. Connect the box to power coming from the ceiling that was supplying power to the old fixture (black and white) 

3) When power is connected to the box lift up the panel and mount the power box in the bracket with the 2 finger screws. 

4) Then mount the panel in the ceiling and switch on the power. 

 

Dimmer Instructions: 

On-Off Wiring (Non-Dimming) 

1) Connect the black fixture lead to the (+) Line Supply lead. 

2) Connect the white fixture lead to the (-) Common supply lead. 

3) Connect the GROUND wire from the fixture to supply ground. 

Dimmable Wiring

1) Connect the black fixture lead to the (+) Line supply lead.

2) Connect the white fixture lead to the (-) Common supply lead.

3) Connect the Ground wire from fixture to supply ground. Do not connect the ground of the dimming fixture to the output.

5) Connect the purple fixture lead to the (V+) dim lead.

6) Cap the yellow fixture lead. Do not connect. 